...the correct ratio of primary turns to secondary turns. Using this test correctly can help to identify tap changer performance, shorted turns, open windings, incorrect winding connections and other faults inside transformers. Features 1. Input single power,
...the correct ratio of primary turns to secondary turns. Using this test correctly can help to identify tap changer performance, shorted turns, open windings, incorrect winding connections and other faults inside transformers. Features 1. Input single power, more
Brand Name:GDZX
Model Number:ZX-BCS
Place of Origin:Hubei, China
-
...transformer turns ratio tester Introduction Before a newly installed transformer is put into operation, and in accordance with the preventive test regulations of the Ministry of Electric Power, the production process of semi-finished and finished power transformers requires testing the turns ratio or voltage ratio of the operating transformer. This includes checking the transformer turns ratio...
...transformer turns ratio tester Introduction Before a newly installed transformer is put into operation, and in accordance with the preventive test regulations of the Ministry of Electric Power, the production process of semi-finished and finished power transformers requires testing the turns ratio or voltage ratio of the operating transformer. This includes checking the transformer turns ratio... more
Brand Name:XZH TEST
Model Number:XHBB128B
Place of Origin:Xi'an city,Shaanxi,China
0.9-10000 Transformer Turn Ratio Tester 3-phase XHBB128B
-
...Transformer Turn Ratio Group Tester 3 Phase TTR Meter Product Description In power transformer in the production of semi-finished products and finished products, before the new installation of the transformer in operation and according to the national ministry of preventive test procedures, require the operation of transformer turn ratio or voltage ratio test, you can check the correctness of the transformer turn
...Transformer Turn Ratio Group Tester 3 Phase TTR Meter Product Description In power transformer in the production of semi-finished products and finished products, before the new installation of the transformer in operation and according to the national ministry of preventive test procedures, require the operation of transformer turn ratio or voltage ratio test, you can check the correctness of the transformer turn more
Brand Name:RISING
Model Number:RSBC
Place of Origin:China
Z Connect Power 10000 Transformer Turn Ratio Tester
-
...Transformer Turn Ratio Test Set MCTTR301 Main Features 1) LCD display 2) Measure single phase or three phase transformer turn ratio 3) Auto switch phase sequence and ranges 4) Auto calculate voltage regulation ratio 5) Ratio measurement & Ratio Error calculation by input standard ratio 6) Can test CT ratio and display excitation current 7) Group vector measurement; can auto measure single&three phase transformer...
...Transformer Turn Ratio Test Set MCTTR301 Main Features 1) LCD display 2) Measure single phase or three phase transformer turn ratio 3) Auto switch phase sequence and ranges 4) Auto calculate voltage regulation ratio 5) Ratio measurement & Ratio Error calculation by input standard ratio 6) Can test CT ratio and display excitation current 7) Group vector measurement; can auto measure single&three phase transformer... more
Brand Name:HNMC
Model Number:MCTTR301
Place of Origin:China
0.2 Class Transformer Test Equipment , 10000 Transformer Turn Ratio Tester
-
... can be applied to test the turns ratio and group vector of single or three phase transformer. The connection group of three phase transformer also can be calculated with the ratio. All parameters can be measured in one test for three phase transformer.
... can be applied to test the turns ratio and group vector of single or three phase transformer. The connection group of three phase transformer also can be calculated with the ratio. All parameters can be measured in one test for three phase transformer. more
Model Number:TTR-I
Place of Origin:China
Certification:ISO9001
TTR-I Single Phase and Three Phase Transformer Turns Ratio Tester
-
...Transformer Turns Ratio Tester is designed according IEC76-1 and IEC60044. It can be applied to test the turns ratio and group vector of single or three phase transformer. The connection group of three phase transformer also can be calculated with the ratio. All parameters can be measured in one test for three phase transformer. Functions of Transformer Turns Ratio Tester: Parameters Testing / Type of Transformer...
...Transformer Turns Ratio Tester is designed according IEC76-1 and IEC60044. It can be applied to test the turns ratio and group vector of single or three phase transformer. The connection group of three phase transformer also can be calculated with the ratio. All parameters can be measured in one test for three phase transformer. Functions of Transformer Turns Ratio Tester: Parameters Testing / Type of Transformer... more
Brand Name:AI
Model Number:TTR-I
Place of Origin:China Mainland
Single Phase and Three Phase Transformer Turns Ratio Tester with Printer
-
1. Product Name: Transformer Ratio Meter HYBC-901 2. Equipment Description: 1 The voltage ratio measurement for three or singe phase transformer 2 The group vector measurement for three phase transformer. 3 The polarity measurement for single phase ...
1. Product Name: Transformer Ratio Meter HYBC-901 2. Equipment Description: 1 The voltage ratio measurement for three or singe phase transformer 2 The group vector measurement for three phase transformer. 3 The polarity measurement for single phase ... more
Brand Name:Huaying
Model Number:Huaying Series
Place of Origin:Wuhan Hubei China
Transformer Turn Ratio Tester
-
1.We not only offer our own stock, but also help clients to search the parts in Chinese market. 2.We have implemented a strict and complete quality control system which ensures that all parts we offer are of good quality. 3.We have experienced workers and ...
-
... for transformer of type Z winding and other transformers whose zero-load current is relatively high. The transfomer turns ratio tester has wide testing range, fast testing speed, favorable repeatability, flexible data processing, convenient connection,
... for transformer of type Z winding and other transformers whose zero-load current is relatively high. The transfomer turns ratio tester has wide testing range, fast testing speed, favorable repeatability, flexible data processing, convenient connection, more
Brand Name:YUYANG
Model Number:TTR-I
Place of Origin:China
Z Type Transformer Turns Ratio Meter 7kg 1 - 10000 Ratio Measurement Range
-
... its commissioning, it is required to test the turns ratio or voltage ratio of transformer according to the requirements of preventive test instructions of State Ministry of electric power. Model BBC-VI three-phase type winding ratio tester, overcoming the
... its commissioning, it is required to test the turns ratio or voltage ratio of transformer according to the requirements of preventive test instructions of State Ministry of electric power. Model BBC-VI three-phase type winding ratio tester, overcoming the more
Brand Name:Fanke High-voltage
Model Number:BBC-VI
Place of Origin:China
Laboratory Power Transformer Testing Equipment Transformer Windi Ratio Tester
-
...Transformer Group Turns Ratio Tester With 58mm printer In power transformer Finished product production process, before the new installation of the transformer in operation, according to the national ministry of preventive test procedures, require the operation of transformer turn ratio or voltage ratio test, to check the correctness of the transformer turn ratio tap-changer of transformer...
...Transformer Group Turns Ratio Tester With 58mm printer In power transformer Finished product production process, before the new installation of the transformer in operation, according to the national ministry of preventive test procedures, require the operation of transformer turn ratio or voltage ratio test, to check the correctness of the transformer turn ratio tap-changer of transformer... more
Brand Name:GFUVE
Model Number:TEST-203
Place of Origin:BEIJING, CHINA
Automatic Power Transformer Electrical Test Equipment Group Turns Ratio Tester
-
Transformer Turns Ratio Meter Model: TTR-400 Transformer Turns Ratio Meter TTR-400 is designed to measure the voltage ratio and turns ratio of singe phase or three-phase distribution transformers or power transformers in a substation or manufacturing environment according to test standard IEC 60076 and IEEE C57.12.90. Main Features ●Measures turns ratio, voltage ratio...
Transformer Turns Ratio Meter Model: TTR-400 Transformer Turns Ratio Meter TTR-400 is designed to measure the voltage ratio and turns ratio of singe phase or three-phase distribution transformers or power transformers in a substation or manufacturing environment according to test standard IEC 60076 and IEEE C57.12.90. Main Features ●Measures turns ratio, voltage ratio... more
Brand Name:HAOMAI
Model Number:TTR-400
Place of Origin:China
IEEE C57.12.90 Transformer Turns Ratio Meter
-
4 Port Network Card Lan Transformer Turns Ratio 50KHz 0.5V ST-81068 Detailed Information: LINK-PP LPB81068NL 100% CROSS ST-81608 LINK-PP Part Number ...
-
MOX-LAN-QP4B-5004 Magnetic Transformer Modules For 1:1 Turns Ratio Transceivers Description: LAN-QP4B-5000 series of surface mount magnetic modules are designed to support 1:1 turns ratio transceivers. Low cost. Sealed bottom case design. RoHS NL peak ...
-
FEATURES: 1:1 Turns Ratio Compliant with IEEE802.3u and ANSI X.3.263 standards including 350 uH OCL with 8mA bias Soldering methods:Wave,Reflow Operating Temperature:0℃ to 70℃ Storage Temperature:-55℃ to 125℃ ELECTRONICAL SPECIFICATIONS : Turns ratio: N1:...
-
...Application: Induction Hardening, Induction Heating Variable's Transformer Connection: In order to give more options for you to connect different coils, so we made a adjustable Transformer for you, the connection way as follows: Secondary connection at the
...Application: Induction Hardening, Induction Heating Variable's Transformer Connection: In order to give more options for you to connect different coils, so we made a adjustable Transformer for you, the connection way as follows: Secondary connection at the more
Brand Name:ORD
Model Number:600KVA
Place of Origin:China
600KVA Multi Turns Ratios Induction Hardening Equipment High Frequency