-
... for 2-wire and 3-wire smart transmitters located in hazardous areas. This device provides a fully-floating DC supply to energize conventional 4-20mA transmitters while accurately repeating the current to drive a safe-area load,
... for 2-wire and 3-wire smart transmitters located in hazardous areas. This device provides a fully-floating DC supply to energize conventional 4-20mA transmitters while accurately repeating the current to drive a safe-area load, more
Brand Name:MTL
Model Number:MTL5541
Place of Origin:England
-
...20mA Current-Loop Transmitter Specifications: Datasheets XTR117 Product Photos 8-MSOP Standard Package 2,500 Category Integrated Circuits (ICs) Family Interface - Sensor and Detector Interfaces Series - Packaging Tape & Reel (TR) Type Current Transmitter Input Type Voltage Output Type Voltage Interface 2-Wire Current - Supply 20mA...
...20mA Current-Loop Transmitter Specifications: Datasheets XTR117 Product Photos 8-MSOP Standard Package 2,500 Category Integrated Circuits (ICs) Family Interface - Sensor and Detector Interfaces Series - Packaging Tape & Reel (TR) Type Current Transmitter Input Type Voltage Output Type Voltage Interface 2-Wire Current - Supply 20mA... more
Brand Name:TI
Model Number:XTR117AIDGKR
Certification:ROHS COMPLIANT
Integrated Circuit Chip XTR117AIDGKR ---- 4-20mA Current-Loop Transmitter
-
...20mA passive loop-powered moduleSelection Example: Example: Signal input 4-20mA , Signal output 4-20mA Model: JSD MI 4-20mA-F Two-wire 4-20mA passive loop-powered moduleFeatures: ◆low cost, small size, SIP12 package with UL94-V0 flame retardant standard ◆Isolation voltage up to 3000VDC between input and output ◆Provide work without external power supply, no external components ◆4 ~ 20mA current input, 4 ~ 20mA current...
...20mA passive loop-powered moduleSelection Example: Example: Signal input 4-20mA , Signal output 4-20mA Model: JSD MI 4-20mA-F Two-wire 4-20mA passive loop-powered moduleFeatures: ◆low cost, small size, SIP12 package with UL94-V0 flame retardant standard ◆Isolation voltage up to 3000VDC between input and output ◆Provide work without external power supply, no external components ◆4 ~ 20mA current input, 4 ~ 20mA current... more
Brand Name:JSD
Model Number:JSD MI 4-20maA-F
Place of Origin:SHENZHEN,CHINA
Two-wire 4-20mA passive loop-powered module
-
... a standard 4-20mA current loop for dual-axis attitude data, it supports long-distance signal transmission up to 2000 meters. It integrates a 3-axis accelerometer and a 3-axis ...
... a standard 4-20mA current loop for dual-axis attitude data, it supports long-distance signal transmission up to 2000 meters. It integrates a 3-axis accelerometer and a 3-axis ... more
Brand Name:RUICOM
Model Number:DTS
Place of Origin:Shenzhen, China
Dynamic Inclinometer DTS6-A1 | 4-20mA Current Output
-
AHKC-EKB hall sensor Open-loop hall current sensor Measuring —AC, DC, pulse and other complex current signals Features —Small package —Low power consumption —Extended measuring range Application —AC variable speed drives —...
-
...20mA Current Source Overview Fluke 789 ProcessMeter doubles your troubleshooting power and is Fluke Connect-enabled The Fluke 789 ProcessMeter is the ultimate troubleshooting tool for electricians and instrumentation professionals. It combines the functionality of a loop...
...20mA Current Source Overview Fluke 789 ProcessMeter doubles your troubleshooting power and is Fluke Connect-enabled The Fluke 789 ProcessMeter is the ultimate troubleshooting tool for electricians and instrumentation professionals. It combines the functionality of a loop... more
Brand Name:Fluke
Model Number:FLUKE787 FLUKE789
Place of Origin:USA
Digital Fluke 787 Process Meter / Fluke Multimeter 789 4 - 20mA Current Source
-
RCV420JP UART Interface IC Sensor Interface Precision 4-20mA Crnt Loop Rcvr FEATURES ● COMPLETE 4-20mA TO 0-5V CONVERSION ● INTERNAL SENSE RESISTORS ● PRECISION 10V REFERENCE ● BUILT-IN LEVEL-SHIFTING ● ±40V COMMON-MODE INPUT RANGE ● 0.1% OVERALL ...
RCV420JP UART Interface IC Sensor Interface Precision 4-20mA Crnt Loop Rcvr FEATURES ● COMPLETE 4-20mA TO 0-5V CONVERSION ● INTERNAL SENSE RESISTORS ● PRECISION 10V REFERENCE ● BUILT-IN LEVEL-SHIFTING ● ±40V COMMON-MODE INPUT RANGE ● 0.1% OVERALL ... more
Brand Name:Ti
Model Number:RCV420JP
Minimum Order Quantity:Contact us
RCV420JP UART Interface IC Sensor Interface Precision 4-20mA Crnt Loop Rcvr
-
...20mA Current Output Sensor Switch Quick detail information : Series : Q40 Analog Inductive Current output sensor Size : 40*40*118mm Housing Material : ABS plastic Mounting : shielded/Non-shielded Sensing Distance Sn(mm) : 15mm/25mm Operating Voltage : DC 18-30V Output function : 4-20mA/0-20mA Specification of the sensor : DC 3 with Q40 Square Analog Inductive Current...
...20mA Current Output Sensor Switch Quick detail information : Series : Q40 Analog Inductive Current output sensor Size : 40*40*118mm Housing Material : ABS plastic Mounting : shielded/Non-shielded Sensing Distance Sn(mm) : 15mm/25mm Operating Voltage : DC 18-30V Output function : 4-20mA/0-20mA Specification of the sensor : DC 3 with Q40 Square Analog Inductive Current... more
Brand Name:Luoshida
Model Number:I1B40*GI-4-20MA
Place of Origin:China
Q40 Square Analog Inductive Proximity Sensor With 4-20mA Current Output Sensor Switch
-
...loop resistance The SXHL-100A is a high current loop resistance measuring instrument intended for checking conductive connection points in power electrical equipment. It can be applied to circuit breakers, busbars, and similar connections where low contact resistance is important for reliable current conduction. The four terminal test configuration improves measurement accuracy by using separate current...
...loop resistance The SXHL-100A is a high current loop resistance measuring instrument intended for checking conductive connection points in power electrical equipment. It can be applied to circuit breakers, busbars, and similar connections where low contact resistance is important for reliable current conduction. The four terminal test configuration improves measurement accuracy by using separate current... more
Brand Name:Sansion Power
Model Number:SXHL-100A
Place of Origin:China
High Current Loop Resistance Measurement Tester with Four Terminal Technology for Switchgear
-
... the device is in operation, it can detect the output signals of each branch sensor in real time. When the branch insulation is normal, the current flowing through the sensor is equal in magnitude and opposite in direction, and its output signal is zero.
... the device is in operation, it can detect the output signals of each branch sensor in real time. When the branch insulation is normal, the current flowing through the sensor is equal in magnitude and opposite in direction, and its output signal is zero. more
Brand Name:IVY
Model Number:MD0630T01A
Place of Origin:Zhejiang
Type B Type EV Use Ac Dc 6mA 30mA 4-20Ma Current Sensor Applications
-
Hot Sell: 4-20mA/0-10V signal isolated splitter/isolated amplifier,one in two out, DIN35 Rail-mounted.Two years warranty,CE approved. Features: >> One input two output >> Accuracy: 0.1%, 0.2% >> Isolation : signal input / output / auxiliary power 3000VDC...
-
Stock Fluke 707 Current Loop Calibrator Key features High performance loop calibrator for calibration, repair, and maintenance Features large display and simple, quick-click interface for easy one-handed operation. Provides ...
Stock Fluke 707 Current Loop Calibrator Key features High performance loop calibrator for calibration, repair, and maintenance Features large display and simple, quick-click interface for easy one-handed operation. Provides ... more
Brand Name:Fluke
Model Number:707
Place of Origin:USA
Stock Fluke 707 Current Loop Calibrator
-
...20mA current signal output, and feeds it to PLC, DCS or DEH systems ,it is small in size, with high accuracy and easy to install. Functions 1.Mianly applying to measuring absolute vibration(i.e.bearing vibration) of rotating machinery. 2.4~20mA analog current output. 3....
...20mA current signal output, and feeds it to PLC, DCS or DEH systems ,it is small in size, with high accuracy and easy to install. Functions 1.Mianly applying to measuring absolute vibration(i.e.bearing vibration) of rotating machinery. 2.4~20mA analog current output. 3.... more
Brand Name:OEM
Model Number:JM-B-3B
Place of Origin:China
Transmitter Series JM-B-3B Vibration Transmitter,4~20mA current signal output
-
Product Description: SS441A Continuous 20mA Current Sink Output Digital lock Single-Pole Hall Effect Sensor Features: SS441A continuous 20mA current sink output digital lock single-pole Hall effect sensor The SS400 series and SS500 series of lock-in ...
-
...Current Loop Calibrator Handheld Auto Signal Generator VICTOR 05S Loop Calibrator high precision Voltage Current Simulation transmitter handheld automatic signal generator VC05S LOOP Calibrator Basic characteristics of the product Input measurement characteristics Basic functions DC voltage DCV, DC current...
-
4-20mA Current Output Signal RGZP6103B1, High Precision Pressure Transmitter for Industrial Process Control and Monitoring FEATURES Range 0~1/1.6/2.5/.../40MPa Power Supply 10~30VDC Output 4~20mA Output Signal Analog signal or I2C interface Construction ...
-
AKF398 CE MEMS Based Accelerometer Sensor 20mA Current Vibration measurement PRODUCT INTRODUCTION The AKF398 triaxial VIBRATION SENSOR is a voltage output type VIBRATION SENSOR independently developed and produced, which can be used in many fields such as ...
AKF398 CE MEMS Based Accelerometer Sensor 20mA Current Vibration measurement PRODUCT INTRODUCTION The AKF398 triaxial VIBRATION SENSOR is a voltage output type VIBRATION SENSOR independently developed and produced, which can be used in many fields such as ... more
Brand Name:RION
Model Number:AKF398
Place of Origin:Guangdong, China
AKF398 CE MEMS Based Vibration Sensor 20mA Current Vibration measurement
-
... 4-20mA CURRENT TRANSMITTER with Sensor Excitation and Linearization FEATURES ● LOW UNADJUSTED ERROR ● TWO PRECISION CURRENT SOURCES: 800µA each ● LINEARIZATION ● 2- OR 3-WIRE RTD OPERATION ● LOW OFFSET DRIFT: 0.4µV/°C ● LOW OUTPUT CURRENT ...
-
...other reasons. 2. The Test procedures require conductive contact resistance testing of various switchgear and cable connectors,the test current shall not be less than 100A. 3. When the high current flows, the temperature of the contact point rises, which
...other reasons. 2. The Test procedures require conductive contact resistance testing of various switchgear and cable connectors,the test current shall not be less than 100A. 3. When the high current flows, the temperature of the contact point rises, which more
Brand Name:MINGYANG
Model Number:MY-505
Place of Origin:Hubei China
200A High Current Loop Resistance Tester for Substation Switch Maintenance