... is controlled by the high-grade single chip microcomputer (SCM), with the digital display, the no load, short circuit and other test data synchronously also sampled by the SCM. It is avoid separately reading the voltmeter, ammeter and power meter in the
... is controlled by the high-grade single chip microcomputer (SCM), with the digital display, the no load, short circuit and other test data synchronously also sampled by the SCM. It is avoid separately reading the voltmeter, ammeter and power meter in the more
Brand Name:RISING
Model Number:RSBTT III
Place of Origin:China
-
... transformer, necessary rutine quality inspection and test items are required. Power Transformer Comprehensive Test Systems are designed and used for the above test purpose. According to the different test items requirements of the customer's order, it
... transformer, necessary rutine quality inspection and test items are required. Power Transformer Comprehensive Test Systems are designed and used for the above test purpose. According to the different test items requirements of the customer's order, it more
Brand Name:Fanke High-Voltage
Model Number:FKBT-III-250KVA
Place of Origin:China
Full Automatic Integrated Transformer Test Bench , Power Transformer Test System
-
... transformer, necessary rutine quality inspection and test items are required. Power Transformer Comprehensive Test Systems are designed and used for the above test purpose. According to the different test items requirements of the customer's order, it
... transformer, necessary rutine quality inspection and test items are required. Power Transformer Comprehensive Test Systems are designed and used for the above test purpose. According to the different test items requirements of the customer's order, it more
Brand Name:Ningbo Suntech Power
Model Number:FKBT-III-250KVA
Place of Origin:Ningbo,China
Full Automatic Integrated Transformer Test Bench , Power Transformer Test System
-
Transformer Testing Equipment 0.1 - 650V Three phase Transformer All-purpose Test Bench Equipment ZX-BCT transformer integrated test bench is suitable for power transformer manufacturers, industrial and mining enterprises. The transformer integrated test platform can truly judge the power transformer no-load current, no-load loss, impedance voltage and load loss, accurately Measure power transformer...
Transformer Testing Equipment 0.1 - 650V Three phase Transformer All-purpose Test Bench Equipment ZX-BCT transformer integrated test bench is suitable for power transformer manufacturers, industrial and mining enterprises. The transformer integrated test platform can truly judge the power transformer no-load current, no-load loss, impedance voltage and load loss, accurately Measure power transformer... more
Brand Name:GDZX
Model Number:ZX-BCT
Place of Origin:China
ZX-BCT All Purpose Min 0.1 Max 650V Three Phase Transformer Test Bench
-
...designed according to IEC62271. The main application of the tester is measurement of circuit breaker contact resistance. All the test results of the tester can be printed by the micro-printer which is integrated in the tester. All the test results saved in
...designed according to IEC62271. The main application of the tester is measurement of circuit breaker contact resistance. All the test results of the tester can be printed by the micro-printer which is integrated in the tester. All the test results saved in more
Brand Name:Pego Tester
Model Number:HYHL-100A
Place of Origin:China
9 KG Transformer Testing Equipment , Contact Resistance Meter 0.1μΩ Resolution
-
... 35kv / 600A Current Transformer Description: The YCCTR-9901 High-Voltage Current Transformer Turn-Ratio Test Set is meticulously crafted for precise on-line evaluation of turn ratios in current transformers rated at up to 10kV. This innovative system
-
Transformer Tan Delta Test Equipment I.Introduction: TDT Tan Delta Test Equipment is an integrated structure, there is a dielectric loss test bridge, a variable frequency power supply, a step-up transformer and a SF6 high stability standard capacitor built-in; This Loss Angle Test Equipment can also supply high voltage source for testing...
Transformer Tan Delta Test Equipment I.Introduction: TDT Tan Delta Test Equipment is an integrated structure, there is a dielectric loss test bridge, a variable frequency power supply, a step-up transformer and a SF6 high stability standard capacitor built-in; This Loss Angle Test Equipment can also supply high voltage source for testing... more
Brand Name:AI
Model Number:TDT
Place of Origin:China
Transformer Test Equipment for Tan Delta Tester Dissipation Factor Test
-
..., type, no-load current, no-load loss, short circuit (load) loss, resistance voltage, etc. KFZ Transformer Load Loss and No Load Loss Testing Transformer Test Equipment is small in volume, light in weight, in high accuracy, with steady property, easy to
..., type, no-load current, no-load loss, short circuit (load) loss, resistance voltage, etc. KFZ Transformer Load Loss and No Load Loss Testing Transformer Test Equipment is small in volume, light in weight, in high accuracy, with steady property, easy to more
Brand Name:Delta
Model Number:KFZ
Place of Origin:China
KFZ Transformer Load Loss and No Load Loss Testing Transformer Test Equipment
-
...Transformer Test Equipment-Transformer Loss Test Set MCTL-100 Main Features 1) Can measure: no- load current (excitation current); no-load loss (core loss); short circuit voltage; short circuit loss (cooper loss); zero-sequence impedance 2) Can automatically adjust: distortion of wave form; temperature; voltage (no-load test under non-rated voltage); current (short circuit test...
...Transformer Test Equipment-Transformer Loss Test Set MCTL-100 Main Features 1) Can measure: no- load current (excitation current); no-load loss (core loss); short circuit voltage; short circuit loss (cooper loss); zero-sequence impedance 2) Can automatically adjust: distortion of wave form; temperature; voltage (no-load test under non-rated voltage); current (short circuit test... more
Brand Name:HNMC
Model Number:MCTL-100
Place of Origin:China
750V Transformer Test Equipment , Portable Transformer Loss Tester
-
...Transformer Test Set Model: CTP-120PA Automatic Instrument Transformer Test Set CTP-120PA is a portable and multifunctional test kit for testing both current transformers and voltage transformers in their equipment configuration, such as being mounted in transformers...
...Transformer Test Set Model: CTP-120PA Automatic Instrument Transformer Test Set CTP-120PA is a portable and multifunctional test kit for testing both current transformers and voltage transformers in their equipment configuration, such as being mounted in transformers... more
Brand Name:HAOMAI
Model Number:CTP-120PA
Place of Origin:China
50/60Hz Current Instrument Transformer Test Set Maximum Knee Voltage 40kV
-
...Connector with integrated transformer for Internet Camera Descriptions: 10/100Base-Tx RJ45 single port 1X1 Vertical with LEDS with side entry Single port 1X1 Tab-Up RJ45 with internal magnetics Internal magnetics are 100% electrically tested for HI-POT...
...Connector with integrated transformer for Internet Camera Descriptions: 10/100Base-Tx RJ45 single port 1X1 Vertical with LEDS with side entry Single port 1X1 Tab-Up RJ45 with internal magnetics Internal magnetics are 100% electrically tested for HI-POT... more
Brand Name:DGKYD
Model Number:KRJ-328NL
Place of Origin:DongGuan of China
WIFI RJ45 Single Port Connector With Integrated Transformer For Internet Camera
-
... error and phase displacement of current transformers. Standard: IEC 61869-2 Instrument transformers - Part 2: Additional requirements for current transformers Current Transformer Testing Equipment configuration: Current transformer tester, the product is
-
...Transformer Test Set CT PT Analyzer Test for current transformer: Excitation curve and parameters test Turns ratio test Ratio and phase error test Polarity mark check Winding resistance measurement Secondary loop burden measurement Error line curve test for protection CT Transient CT parameters test CT nameplate guess Saturation hysteresis loop curve measurement Tests for Potencial Transformer: Turns ratio test
...Transformer Test Set CT PT Analyzer Test for current transformer: Excitation curve and parameters test Turns ratio test Ratio and phase error test Polarity mark check Winding resistance measurement Secondary loop burden measurement Error line curve test for protection CT Transient CT parameters test CT nameplate guess Saturation hysteresis loop curve measurement Tests for Potencial Transformer: Turns ratio test more
Brand Name:YUYANG
Model Number:CPT-I
Place of Origin:China
Current And Potential Transformer Test Set CT PT Analyzer
-
... ● Various Busbar Integration to Adapt Application 2.Technical Parameters: Main Parameter Current Ratio 5(60)A/2mA Coil Turns 2500 Burden 20Ω ...
-
...Transformer Test Bench is applied for ex-work and maintenance detecting on various transformers. It´s widely used in the fields of power supply and distribution, power transformer manufacturer, transformer maintenance center,industry and mining enterprises. Features Applied for different voltage degree transformers, reactors and HV switchgears. Fully PLC controlling and measurement, integrated...
-
TEST-905 5000A 25KVA CAPICITY PRIMARY CURRENT INJECTION TEST SYSTEM FOR POWER TRANSFORMER TESTING 5000A 25KVA CAPICITY PRIMARY CURRENT INJECTION TEST SYSTEM FOR POWER TRANSFORMER TESTING TEST-905 primary current injection test system adopts ARM chip to control the output process and large capacity of toroidal transformer...
TEST-905 5000A 25KVA CAPICITY PRIMARY CURRENT INJECTION TEST SYSTEM FOR POWER TRANSFORMER TESTING 5000A 25KVA CAPICITY PRIMARY CURRENT INJECTION TEST SYSTEM FOR POWER TRANSFORMER TESTING TEST-905 primary current injection test system adopts ARM chip to control the output process and large capacity of toroidal transformer... more
Brand Name:GFUVE
Model Number:TEST-905
Place of Origin:BEIJING CHINA
5000a 25kva Capicity Primary Current Injection Test Set For Power Transformer Testing
-
... Harmonic test can be analyzed to 31 harmonics. 3. Support Three Methods, two table method, two experimental methods. 4. Do three-phase transformer no-load, load test, GDKF Transformer Load and No Load Loss Tester can automatically determine the wiring is
... Harmonic test can be analyzed to 31 harmonics. 3. Support Three Methods, two table method, two experimental methods. 4. Do three-phase transformer no-load, load test, GDKF Transformer Load and No Load Loss Tester can automatically determine the wiring is more
Brand Name:Huaying
Model Number:Huaying Series
Place of Origin:Wuhan Hubei China
Power Transformer Testing Equipment Load and No-load tester HYKF